Modern seagoing ships are supplied by at least 4 large diesel generators which are operated in an unearthed system. Monitoring for insulation faults using the common 3 lamp method is neither safe nor conforming to standards. The use of modern methods based on the AMP measurement principle also makes sense due to the massive frequency converters used. It must also always be guaranteed that the partially coupled generators are safely monitored. Bender ISOMETER®s achieve this. One of the key components of shipping engineering is the main machine with its auxiliary generators, kettle systems, auxiliary diesel and the generators for power generation and loading pumps. The main distribution boards on-board the tankers are generally designed as unearthed systems which are monitored with ISOMETER®s and fault locators.
Tipo | Nome | Dimensione | Lingua | Timestamp | D-/B-Numero |
---|---|---|---|---|---|
Flyer | Power Quality | 468.0 KB | EN | 2022/12/14 08:20:2814.12.2022 08:20:28 | |
Nota di applicazione | EDS309x | 1.4 MB | EN | 2019/05/13 10:30:3813.05.2019 10:30:38 | D00012 |
Articolo tecnico | Insulation Fault Location - Planning and Setup | 112.4 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 | |
Articolo tecnico | Electrical Safety in Control and Auxiliary Circuits | 632.6 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 | |
Articolo tecnico | The “Oasis of the Seas”: A Cruise Ship of Superlatives | 340.0 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 | |
Technical information | A Safe Trip all the Time – with Reliable Power Supply | 502.0 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 |
Prodotti
Controllore d'isolamento per applicazioni impegnative
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
Localizzatore di guasti di isolamento con 6 trasformatori di corrente di misura integrati per la ricerca di guasti di isolamento nei circuiti di controllo.
Localizzatore di guasti di isolamento con 6 trasformatori di corrente di misura integrati per la ricerca di guasti di isolamento nei circuiti principali.
Apparecchiature portatili per la localizzazione di guasti di isolamento su reti isolate da terra e con neutro a terra (sistemi IT e TN).
Localizzatore di guasti di isolamento per individuare guasti di isolamento nei circuiti principali.
Localizzatore di guasti di isolamento per individuare guasti di isolamento nei circuiti di controllo.
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding
L'avanzato monitor di resistenza di terra per applicazioni impegnative
Controllore d'isolamento per applicazioni impegnative
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
Localizzatore di guasti di isolamento con 6 trasformatori di corrente di misura integrati per la ricerca di guasti di isolamento nei circuiti di controllo.
Localizzatore di guasti di isolamento con 6 trasformatori di corrente di misura integrati per la ricerca di guasti di isolamento nei circuiti principali.
Apparecchiature portatili per la localizzazione di guasti di isolamento su reti isolate da terra e con neutro a terra (sistemi IT e TN).
Localizzatore di guasti di isolamento per individuare guasti di isolamento nei circuiti principali.
Localizzatore di guasti di isolamento per individuare guasti di isolamento nei circuiti di controllo.
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 01.01.2025
Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding
L'avanzato monitor di resistenza di terra per applicazioni impegnative
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 8: Dispositivi per il controllo dell'isolamento per sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Apparecchi per prove, misure o controllo dei sistemi di protezione - Parte 9: Apparecchi per la risoluzione dei problemi di isolamento nei sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 15: Prescrizioni per la sicurezza funzionale dei dispositivi di controllo dell'isolamento nei sistemi IT e dei dispositivi per la rilevazione dei guasti di isolamento nei sistemi IT
Dotare gli impianti di potenza di apparecchiature elettroniche
Sicurezza del macchinario - Equipaggiamento elettrico delle macchine - Parte 1: Regole generali
Electrical installations in ships - Part 504: Automation, control and instrumentation
Electrical installations in ships - Part 202: System design - Protection
Electrical installations in ships - Part 502: Tankers - Special features
Electrical installations in ships - Part 201: System design - General
For port operators and shipbuilders, setting up an onshore power supply represents a considerable undertaking. Transformer stations and cables to the quay need to be set up on land. These are mostly brought on-board via booms and connected to one or more points. Not only the tides, but also the International Ship and Port Facility Security Code must be taken into consideration. It is important that the monitoring equipment on board the ship and on shore are synchronised as otherwise there can be problems with fault detection. Bender products can be set up so that there are not two measuring systems in a single power circuit. Ask us!
Tipo | Nome | Dimensione | Lingua | Timestamp | D-/B-Numero |
---|---|---|---|---|---|
Articolo tecnico | Electrical Safety in Control and Auxiliary Circuits | 632.6 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 | |
Nota di applicazione | Application Note onshore PE monitor | 279.5 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 | D00252 |
Prodotti
Controllore d'isolamento per applicazioni impegnative
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
Controllore d'isolamento per circuiti di controllo AC/DC isolati da terra (sistemi IT)
Estensione della tensione nominale per gli ISOMETER® della serie iso685 a AC, 3(N)AC 0...1650/0...1300 V
Estensione della tensione nominale per gli ISOMETER® a AC 0...7200 V
Estensione della tensione nominale per l'ISOMETER® IRDH275BM-7 fino a 0...15,5 kV AC/DC
Estensione della tensione nominale per gli ISOMETER® delle serie iso685, IRDH275-4xx, IRDH375-4xx e IR420-D64 a 0...12 kV AC
L'avanzato monitor di resistenza di terra per applicazioni impegnative
Controllore d'isolamento per applicazioni impegnative
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
Controllore d'isolamento per circuiti di controllo AC/DC isolati da terra (sistemi IT)
Estensione della tensione nominale per gli ISOMETER® della serie iso685 a AC, 3(N)AC 0...1650/0...1300 V
Estensione della tensione nominale per gli ISOMETER® a AC 0...7200 V
Estensione della tensione nominale per l'ISOMETER® IRDH275BM-7 fino a 0...15,5 kV AC/DC
Estensione della tensione nominale per gli ISOMETER® delle serie iso685, IRDH275-4xx, IRDH375-4xx e IR420-D64 a 0...12 kV AC
L'avanzato monitor di resistenza di terra per applicazioni impegnative
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 8: Dispositivi per il controllo dell'isolamento per sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Apparecchi per prove, misure o controllo dei sistemi di protezione - Parte 9: Apparecchi per la risoluzione dei problemi di isolamento nei sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 15: Prescrizioni per la sicurezza funzionale dei dispositivi di controllo dell'isolamento nei sistemi IT e dei dispositivi per la rilevazione dei guasti di isolamento nei sistemi IT
Electrical installations in ships - Part 201: System design - General
Electrical installations in ships - Part 502: Tankers - Special features
Electrical installations in ships - Part 202: System design - Protection
Electrical installations in ships - Part 504: Automation, control and instrumentation
Accommodation and cabins on ships can be exposed to problems with the electrical system within seconds which can only be found manually with a great deal of time and experience. This involves the risk of electric shock and machine downtime. With a multi-channel residual current system, an emerging problem can be detected, reported and repaired quickly.
Tipo | Nome | Dimensione | Lingua | Timestamp | D-/B-Numero |
---|---|---|---|---|---|
Articolo tecnico | Electrical Safety in Control and Auxiliary Circuits | 632.6 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 | |
Articolo tecnico | The “Oasis of the Seas”: A Cruise Ship of Superlatives | 340.0 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 |
Prodotti
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.
AC/DC sensitive measuring current transformer (Type B)
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.
AC/DC sensitive measuring current transformer (Type B)
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 8: Dispositivi per il controllo dell'isolamento per sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Apparecchi per prove, misure o controllo dei sistemi di protezione - Parte 9: Apparecchi per la risoluzione dei problemi di isolamento nei sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 15: Prescrizioni per la sicurezza funzionale dei dispositivi di controllo dell'isolamento nei sistemi IT e dei dispositivi per la rilevazione dei guasti di isolamento nei sistemi IT
Electrical installations in ships - Part 201: System design - General
Electrical installations in ships - Part 502: Tankers - Special features
Electrical installations in ships - Part 202: System design - Protection
Electrical installations in ships - Part 504: Automation, control and instrumentation
The galleys on ships are very prone to electrical faults which can only be detected manually with plenty of experience and a great deal of time. Especially the grills and steamers often cause problems. In all these applications, people can be injured or killed. With a multi-channel residual current system, an emerging problem can be detected much earlier than with a conventional RCD system and repaired before it becomes critical. Another advantage: The whole galley does not have to be shut down if one device is faulty.
Tipo | Nome | Dimensione | Lingua | Timestamp | D-/B-Numero |
---|---|---|---|---|---|
Articolo tecnico | Electrical Safety in Control and Auxiliary Circuits | 632.6 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 | |
Articolo tecnico | The “Oasis of the Seas”: A Cruise Ship of Superlatives | 340.0 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 |
Prodotti
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.
AC/DC sensitive measuring current transformer (Type B)
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.
Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.
AC/DC sensitive measuring current transformer (Type B)
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 8: Dispositivi per il controllo dell'isolamento per sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Apparecchi per prove, misure o controllo dei sistemi di protezione - Parte 9: Apparecchi per la risoluzione dei problemi di isolamento nei sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 15: Prescrizioni per la sicurezza funzionale dei dispositivi di controllo dell'isolamento nei sistemi IT e dei dispositivi per la rilevazione dei guasti di isolamento nei sistemi IT
Electrical installations in ships - Part 201: System design - General
Electrical installations in ships - Part 502: Tankers - Special features
Electrical installations in ships - Part 202: System design - Protection
Electrical installations in ships - Part 504: Automation, control and instrumentation
On all ships, it is important that they remain fully controllable in all situations and, for example, the radar, sonar and weapons systems are operational at all times. Insulation monitoring devices from Bender can easily handle what are sometimes very high-frequency currents and guarantee continuous operation in every situation. Any electrical faults in parts of the whole system are quickly detected and reported and can then be repaired or replaced within a short space of time.
Tipo | Nome | Dimensione | Lingua | Timestamp | D-/B-Numero |
---|---|---|---|---|---|
Articolo tecnico | Electrical Safety in Control and Auxiliary Circuits | 632.6 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 | |
Articolo tecnico | "Cavour" Aids Relief Operation | 389.0 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 |
Prodotti
Controllore d'isolamento per applicazioni impegnative
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
Controllore d'isolamento per applicazioni impegnative
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
- Questa serie di dispositivi è in fase di dismissione. -
Consegnabile secondo disponibilità fino al 31.12.2023
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 8: Dispositivi per il controllo dell'isolamento per sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Apparecchi per prove, misure o controllo dei sistemi di protezione - Parte 9: Apparecchi per la risoluzione dei problemi di isolamento nei sistemi IT
Sicurezza elettrica nelle reti a bassa tensione fino a 1 000 V AC e 1 500 V DC - Dispositivi per prove, misure o controllo dei sistemi di protezione - Parte 15: Prescrizioni per la sicurezza funzionale dei dispositivi di controllo dell'isolamento nei sistemi IT e dei dispositivi per la rilevazione dei guasti di isolamento nei sistemi IT
Electrical installations in ships - Part 201: System design - General
Electrical installations in ships - Part 502: Tankers - Special features
Electrical installations in ships - Part 202: System design - Protection
Electrical installations in ships - Part 504: Automation, control and instrumentation
In terms of equipment, sanitary areas on board ships are similar to those in large doctors’ surgeries or small hospitals with their own operating theatres. Bender is also a capable partner in this area.
Tipo | Nome | Dimensione | Lingua | Timestamp | D-/B-Numero |
---|---|---|---|---|---|
Articolo tecnico | Electrical Safety in Control and Auxiliary Circuits | 632.6 KB | EN | 2019/05/13 10:29:2213.05.2019 10:29:22 |