Serverueberwachung_2000x350

Monitoraggio di server e rack

An IT environment requires either an in-house server room or a service from an external data centre operator. This server room must be easily accessible and the power supply must be secured so that it is fail-safe. Monitored power distribution boards have active measured value recording and AC/DC sensitive fault current monitoring to optimise energy use and protect against unwanted interruptions of power circuits. User-definable threshold values and local or remote alarms highlight and warn of any errors and reduce the risk of unwanted shutdown or overloading of power circuits. They record fault current monitoring and energy consumption data and are available in real time, so that data centre managers can make sound decisions regarding necessary maintenance measures, load distribution and the correct sizing of the IT environments and thus reduce overall operating costs. According to the BITKOM planning guide for operationally safe data centres, one or more residual current monitoring systems must be used in the feed to the racks in order to guarantee continuous monitoring without shutdown. All information collected by the RCMS is then forwarded via a gateway to a permanently manned office, e.g. the control centre. Alternately, there are also PDUs with built-in Bender intelligence, e.g. from Bachmann.

 

Richieda un consiglio

Scaricamento

TipoNomeDimensioneLinguaTimestampD-/B-Numero
Flyer Power Quality 468.0 KB EN2022/05/25 07:22:0425.05.2022 07:22:04
Technical information DATEV eG Achieves Higher Data Center Availability and Reduces Downtime Through the Application of Bender Residual Current Monitoring Technology 913.0 KB EN2019/05/13 10:29:2313.05.2019 10:29:23
Articolo tecnico Uniterrupted Security 2.1 MB EN2019/05/13 10:29:2213.05.2019 10:29:22
Flyer Residual Current Monitoring for IT Computing Devices 753.4 KB EN2019/05/13 10:31:3813.05.2019 10:31:38

Prodotti

Power Quality

LINETRAXX® PEM353

Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding

Controllo delle correnti differenziali

LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D

Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).

LINETRAXX® RCMS460-L
LINETRAXX® RCMS460-L

Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).

LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D

Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.

LINETRAXX® RCMS490-L
LINETRAXX® RCMS490-L

Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.

Trasformatori amperometrici

LINETRAXX® CTUB100 series

AC/DC sensitive measuring current transformer (Type B)

Comunicazione

COMTRAXX® COM465IP

Gateway con web server integrato per la connessione dei dispositivi Bender alle reti Ethernet TCP/IP. Controllo dello stato opzionale.

Powerscout
POWERSCOUT®

Individuare le correlazioni - ottimizzare la manutenzione.

Power Quality

LINETRAXX® PEM353

Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding

Dettagli

Controllo delle correnti differenziali

LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D

Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).

Dettagli
LINETRAXX® RCMS460-L
LINETRAXX® RCMS460-L

Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B).

Dettagli
LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D

Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.

Dettagli
LINETRAXX® RCMS490-L
LINETRAXX® RCMS490-L

Apparecchio multicanale di monitoraggio della corrente differenziale in corrente alternata e pulsata (tipo A) o universale (tipo B), con un contatto di segnalazione per canale.

Dettagli

Trasformatori amperometrici

LINETRAXX® CTUB100 series

AC/DC sensitive measuring current transformer (Type B)

Dettagli

Comunicazione

COMTRAXX® COM465IP

Gateway con web server integrato per la connessione dei dispositivi Bender alle reti Ethernet TCP/IP. Controllo dello stato opzionale.

Dettagli
Powerscout
POWERSCOUT®

Individuare le correlazioni - ottimizzare la manutenzione.

Dettagli

Standard

DIN VDE 0100-731

Errichten von Niederspannungsanlagen - Teil 7-731: Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art – Abgeschlossene elektrische Betriebsstätten

ETSI EN 301605

Environmental Engineering (EE); Earthing and bonding of 400 VDC Data and Telecom (ICT) Equipment - Erdung und Potentialausgleich von Einrichtungen der Informations- und Kommunikationstechnik mit DC 400 V in Rechenzentren und in Betriebsgebäuden der Telekommunikationstechnik (Anerkennung der Englischen Fassung EN 301 605 V1.1.1 (2013-10) als Deutsche Norm)

qhy4raey

Ha qualche domanda?

Contattateci! Il nostro personale sarà felice di aiutarvi.

al modulo di contatto