The multi-functional voltage relays of the VMD420 series are designed to monitor the frequency, undervoltage and overvoltage and the voltage between two threshold values (window discriminator function) in 3(N)AC systems. The voltages are measured as r.m.s. values. The currently measured value is continuously shown on the LC display. The measured value leading to the activation of the alarm relays will be stored. Due to adjustable response times, installation-specific characteristics, such as device-specific start-up procedures, short-time voltage fluctuations, etc. can be considered . Device version VMD420 requires an external supply voltage.
The multi-functional voltage relays of the VMD420 series are designed to monitor the frequency, undervoltage and overvoltage and the voltage between two threshold values (window discriminator function) in 3(N)AC systems. The voltages are measured as r.m.s. values. The currently measured value is continuously shown on the LC display. The measured value leading to the activation of the alarm relays will be stored. Due to adjustable response times, installation-specific characteristics, such as device-specific start-up procedures, short-time voltage fluctuations, etc. can be considered . Device version VMD420 requires an external supply voltage.
Type | Supply voltage US* | Nominal system voltage Un* | Art. No.** |
---|---|---|---|
VMD420-D-1 | AC 16…72 V / DC 9,6…94 V, 15…460 Hz | 3(N)AC 0…500 V / 288 V 15…460 Hz | B73010005 B93010005 |
VMD420-D-2 | AC/DC 70…300 V, 15…460 Hz | 3(N)AC 0…500 V / 288 V, 15…460 Hz | B73010006 B93010006 |
* absolute values
**(B7… = push-wire terminal / B9… = screw-type terminal)
Type | Art. No. |
---|---|
Mounting clip for screw mounting (one piece per device) | B98060008 |
Mounting frame XM420 | B990994 |
Nome | Tipo | Dimensione | Lingua | Timestamp | D-/B-Numero |
---|---|---|---|---|---|
UKCA - VMx42x | Dichiarazioni di conformità | 156.3 KB | 2024/10/0707.10.2024 | ||
TÜV NORD - isoHV42x, AGH42x, isoHV52x, isoRW42x and VMx420 | Certificatos | 416.9 KB | EN | 2024/06/2626.06.2024 | |
TÜV NORD - isoHV42x, AGH42x, isoHV52x, isoRW42x und VMx420 | Certificatos | 436.9 KB | DE | 2024/06/2626.06.2024 | |
VMx42x | Dichiarazioni di conformità CE | 104.6 KB | 2024/10/0707.10.2024 | ||
VMD420 | Manuali di istruzioni | 5.7 MB | DE | 2022/06/0909.06.2022 | D00137 |
VMD420 | Manuali di istruzioni | 5.7 MB | EN | 2022/06/0909.06.2022 | D00137 |
VMD420 | Manuali di istruzioni | 844.6 KB | ES | 2019/05/1313.05.2019 | D00137 |
VMD420 | Data sheet | 374.0 KB | DE | 2022/06/0909.06.2022 | D00137 |
VMD420 | Data sheet | 372.2 KB | EN | 2022/08/1010.08.2022 | D00137 |
VMD420 | Data sheet | 375.7 KB | ES | 2022/06/0909.06.2022 | D00137 |
VMD420 | Data sheet | 540.4 KB | ZH | 2019/05/1313.05.2019 | D00137 |
XM420-Schnittstellenoptionen | Data sheet | 264.1 KB | DE | 2019/05/1313.05.2019 | |
XM420 interface options | Data sheet | 223.5 KB | EN | 2019/05/1313.05.2019 | D00051 |
VMD420 | Quickstarts | 964.6 KB | DE | 2024/05/2323.05.2024 | D00137 |
VMD420 | Quickstarts | 964.6 KB | EN | 2024/05/2323.05.2024 | D00137 |
Changed variants of relays from goldplated to silver-plated contacts | Technical information | 166.3 KB | EN | 2022/06/2727.06.2022 | |
Geänderte Relaisvarianten von vergoldeten Kontakten auf versilberte Kontakte | Technical information | 166.3 KB | DE | 2022/06/2727.06.2022 |