LINETRAXX® RCM420

The AC and pulsed DC sensitive residual current monitor RCM420-D (Type A) from Bender is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. In addition, the device can be used to monitor single conductors, such as PE conductors, N-PE connections and PE-PAS connections.

The prewarning stage (50…100 % of the set response value IΔn2) allow to distinguish between prewarning and alarm. Since the values are measured with measuring current transformers, the device is nearly independent of the load current and the nominal voltage of the system.

Domande? Contattaci!

LINETRAXX® RCM420
LINETRAXX® RCM420

The AC and pulsed DC sensitive residual current monitor RCM420-D (Type A) from Bender is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. In addition, the device can be used to monitor single conductors, such as PE conductors, N-PE connections and PE-PAS connections.

The prewarning stage (50…100 % of the set response value IΔn2) allow to distinguish between prewarning and alarm. Since the values are measured with measuring current transformers, the device is nearly independent of the load current and the nominal voltage of the system.

Domande? Contattaci!

Caratteristiche

  • AC and pulsed DC sensitive residual current monitor Type A according to IEC 62020
  • r.m.s. value measurement (AC)
  • Two separately adjustable response values
  • Frequency range 42…2000 Hz
  • Start-up delay, response delay and delay on release
  • Restart function
  • Digital measured value display via LC display
  • Measured value memory for operating value
  • CT connection monitoring
  • LEDs: Power On, Alarm 1, Alarm 2
  • Internal/external test/reset button
  • Two separate alarm relays (one changeover contact each)
  • N/O or N/C operation and fault memory behaviour selectable
  • Password protection for device setting
  • Device self monitoring
  • Sealable transparent cover
  • Two-module enclosure (36 mm)
  • RoHS compliant
  • Push-wire terminal (two terminals per connection)

Applicazioni

  • Residual current monitoring in earthed two, three or four conductor systems
  • Current monitoring of single conductors de-energised under normal conditions
  • Socket-outlet circuits for devices which are operated unattended for a long time and which may not fail
  • Alarm systems, safety devices
  • Air conditioning systems, EDP systems
  • Cooling equipment with valuable frozen goods
  • Canteen kitchens
  • Monitoring of earthed power supplies for stray currents
  • Impact on N conductors
  • Trace heating systems

LINETRAXX® RCM420 Variante/i

TypeResponse range IΔnFrequency rangeSupply voltage US*Art. No.
RCM420-D-110 mA…10 A42…2000 HzDC 9,6…94 V /
AC 16…72 V, 42…460 Hz
B74014001
B94014001
RCM420-D-210 mA…10 A42…2000 HzDC 70…300 V /
AC 70…300 V, 42…460 Hz
B74014002
B94014002

* Absolute values
**(B7… = push-wire terminal / B9… = screw-type terminal)

Accessori opzionali per LINETRAXX® RCM420

External measuring current transformers

TypeInside diameter (mm)Art. No.
CTAC20ø 20B98110005
CTAC35ø 35B98110007
CTAC60ø 60B98110017
CTAC120ø 120B98110019
CTAC210ø 210B98110020
WR70x17570 x 175B98080609
WR115x305115 x 305B98080610
WS20x3020 x 30B98080601
WS50x8050 x 80B98080603
WS80x12080 x 120B98080606

Accessories

TypeArt. No.
Mounting clip for screw mounting (one piece per device)B98060008
Mounting frame XM420B990994 

Download per LINETRAXX® RCM420

NomeTipoDimensioneLinguaTimestampD-/B-Numero
UKCA - RCM42x Dichiarazioni di conformità 122.4 KB 2023/02/1313.02.2023
RCM42x Dichiarazioni di conformità CE 88.0 KB 2023/10/1919.10.2023
RCM420 Manuali di istruzioni 11.2 MB DE2023/12/1414.12.2023D00057
RCM420 Manuali di istruzioni 11.2 MB EN2023/12/1414.12.2023D00057
RCM420 Manuali di istruzioni 736.1 KB ES2019/05/1313.05.2019D00057
RCM420 Manuali di istruzioni 747.0 KB FR2019/05/1313.05.2019D00057
RCM420 Data sheet 342.3 KB DE2023/07/3131.07.2023D00057
RCM420 Data sheet 336.3 KB EN2023/07/3131.07.2023D00057
RCM420 Data sheet 339.1 KB ES2023/07/3131.07.2023D00057
RCM420 Data sheet 497.1 KB ZH2019/05/1313.05.2019D00057
XM420-Schnittstellenoptionen Data sheet 264.1 KB DE2019/05/1313.05.2019
XM420 interface options Data sheet 223.5 KB EN2019/05/1313.05.2019D00051
RCM420 Quickstarts 510.3 KB DE2023/11/1616.11.2023D00057
RCM420 Quickstarts 510.3 KB EN2023/11/1616.11.2023D00057
Changed variants of relays from goldplated to silver-plated contacts Technical information 166.3 KB EN2022/06/2727.06.2022
Geänderte Relaisvarianten von vergoldeten Kontakten auf versilberte Kontakte Technical information 166.3 KB DE2022/06/2727.06.2022